Ask “what’s the exposure limit for H2S?” and you’ll get four different numbers. Here’s which agency set each one, what it means, and which one your gas monitor is probably using.

Hydrogen sulfide has three commonly quoted limits: OSHA’s enforceable 20 ppm ceiling with a 50 ppm ten-minute peak (29 CFR 1910.1000 Table Z-2), NIOSH’s recommended 10 ppm ten-minute ceiling, and ACGIH’s 1 ppm eight-hour TLV with a 5 ppm short-term limit. NIOSH’s 100 ppm IDLH marks the escape-now threshold.

OSHA: The Enforceable Limits

  • General industry: 20 ppm ceiling. Exposure may go above 20 ppm, but never above 50 ppm, for a single period of up to 10 minutes — and only if there is no other measurable exposure during the 8-hour shift.
  • Construction and shipyards: 10 ppm as an 8-hour time-weighted average.

These are the legal limits OSHA cites against. They’re also the oldest of the numbers here.

NIOSH: The Recommended Limit

NIOSH, the federal research agency for worker safety, recommends a 10 ppm ceiling for any 10-minute period. NIOSH also sets the IDLH — Immediately Dangerous to Life or Health — at 100 ppm: a concentration that can kill or cause permanent harm, or keep a worker from being able to escape.

ACGIH: The Most Protective Limit

In 2010, the American Conference of Governmental Industrial Hygienists lowered its Threshold Limit Value to 1 ppm as an 8-hour average, with a 5 ppm short-term limit. TLVs aren’t law, but many employers, contractors, and oil and gas operators adopt them because they reflect newer research.

What Your Monitor Is Probably Set To

Alarm set points are a company decision, not a single national rule. Older programs commonly used 10 ppm for the low alarm and 15 ppm for the high alarm; many programs now set them closer to the ACGIH values. Always know your site’s set points and what each alarm requires you to do — and remember that you can’t rely on smell, because H2S dulls your sense of smell at dangerous concentrations.

Quick Reference

  • OSHA general industry: 20 ppm ceiling (50 ppm peak, 10 min, once)
  • OSHA construction: 10 ppm TWA
  • NIOSH REL: 10 ppm, 10-minute ceiling
  • ACGIH TLV: 1 ppm TWA, 5 ppm STEL
  • IDLH: 100 ppm

Frequently asked questions

Which H2S limit is legally enforceable?

OSHA’s: a 20 ppm ceiling and one 50 ppm peak of up to 10 minutes per shift in general industry. Construction and maritime use a 10 ppm eight-hour TWA.

What is the ACGIH TLV for H2S?

1 ppm as an eight-hour time-weighted average and 5 ppm as a 15-minute short-term exposure limit, the most protective of the three.

Why set monitors below the OSHA limit?

OSHA’s Table Z-2 values date from 1971. NIOSH and ACGIH reflect newer evidence, and many employers set alarms at 10 and 15 ppm to stay under all three.

Sources: OSHA 29 CFR 1910.1000 Table Z-2 — Limits for air contaminants; NIOSH Pocket Guide — Hydrogen sulfide; NIOSH — Hydrogen sulfide IDLH documentation; OSHA Safety and Health Topics — Hydrogen Sulfide