They get lumped together as "LOTO," but lockout and tagout are two different levels of protection — and one of them physically prevents a machine from starting, the other doesn’t.

Lockout physically prevents a machine from being energized with a lock on the energy-isolating device; tagout only attaches a warning tag. OSHA 29 CFR 1910.147(c)(2) requires lockout wherever the device is capable of being locked, and allows tagout alone only when the employer shows it provides full equivalent protection.

Lockout: Physical Prevention

A lockout device — a padlock applied to an energy-isolating device like a breaker or valve — physically prevents the machine from being re-energized. Nobody can start the equipment without removing the lock, and only the person who applied it is supposed to be able to remove it.

Tagout: A Warning, Not a Barrier

A tagout device is a warning tag attached to the same isolation point. It tells anyone who sees it not to operate the equipment — but it doesn’t physically stop them from doing so. The tag relies entirely on the person seeing it and respecting it.

Because of that gap, OSHA requires extra training whenever tagout is used instead of lockout. Employees need to understand specifically that tags:

  • Are warning devices only — they do not physically restrain anyone from operating the equipment
  • Must never be bypassed, ignored, or defeated
  • Must be legible and understandable to every employee in the area
  • May only be removed by the person who applied them

Why Lockout Is Generally Preferred

Given the choice, lockout is the stronger control because it removes the possibility of human error — there’s no scenario where someone accidentally starts the machine despite a physical lock, the way there is with a tag someone might not notice or might choose to ignore. Tagout is typically used only when equipment genuinely can’t be locked out.

Both Require the Same Underlying Procedure

Whether a specific piece of equipment uses lockout or tagout, the surrounding procedure is the same: identify energy sources, notify affected employees, shut down properly, isolate all energy, apply the device, release stored energy, and verify a zero-energy state before work begins.

Frequently asked questions

Is tagout alone ever allowed?

Only if the energy-isolating device cannot be locked out, or the employer demonstrates that its tagout program gives protection equivalent to lockout, with additional measures such as removing a fuse or blocking a control switch (1910.147(c)(3)).

Who removes a lockout device?

The employee who applied it. 1910.147(e)(3) allows removal by someone else only under a documented procedure that verifies the employee is not at the facility and informs them before they return.

Do new machines have to be lockable?

Yes. Since January 2, 1990, equipment installed, replaced or renovated must have energy-isolating devices designed to accept a lockout device (1910.147(c)(2)(iii)).

Sources: OSHA 29 CFR 1910.147 — The control of hazardous energy (lockout/tagout); OSHA Safety and Health Topics — Control of Hazardous Energy

Get LOTO certified online

Related guides