Fire Extinguisher Classes Explained: A, B, C, D, K

Grabbing the nearest extinguisher isn’t always the right move — using the wrong class on the wrong fire can make things worse, not better.

Fire extinguishers are classed by the fuel they are made for: Class A ordinary combustibles, Class B flammable liquids and gases, Class C energized electrical equipment, Class D combustible metals, and Class K cooking oils and fats. OSHA 29 CFR 1910.157 sets placement by class, with 75 feet maximum travel distance for Class A and 50 feet for Class B.

The Five Classes

  • Class A — ordinary combustibles: wood, paper, cloth, most plastics
  • Class B — flammable liquids and gases: gasoline, oil, solvents, propane
  • Class C — energized electrical equipment: wiring, panels, motors, powered tools
  • Class D — combustible metals: magnesium, sodium, titanium, and similar alloys that can react explosively with water
  • Class K — cooking oils and fats, common in commercial kitchens

Why Water Isn’t a Universal Answer

Water works well on Class A fires, but it’s genuinely dangerous on a Class C (energized electrical) fire because of shock risk, and it can cause a violent reaction on Class D combustible metal fires. Multi-purpose dry chemical extinguishers rated for A, B, and C cover the most common workplace scenarios, but Class D and Class K fires need their own specific, dedicated extinguishing agents.

Placement Requirements Under 1910.157

  • Travel distance, Class A hazards: no more than 75 feet
  • Travel distance, Class B hazards: no more than 50 feet
  • Mounting height (40 lbs or less): top no more than 5 feet above floor
  • Mounting height (over 40 lbs): top no more than 3.5 feet above floor

Inspection Isn’t a One-Time Thing

Extinguishers need a monthly visual inspection — checking the pressure gauge, pin, and seal — plus a more thorough annual maintenance inspection. Violations of the fire extinguisher standard can carry penalties up to $16,550 per instance, and a surprising number of citations come from something as simple as an extinguisher mounted too high or blocked by stored materials.

Frequently asked questions

What is a Class K fire extinguisher for?

Commercial cooking fires in oils and fats. Its wet-chemical agent saponifies the oil; water or a dry chemical can spread a grease fire.

How far apart do fire extinguishers have to be?

Travel distance to a Class A extinguisher may not exceed 75 feet and to a Class B extinguisher 50 feet (1910.157(d)).

How often are extinguishers inspected?

A visual inspection monthly and a maintenance check annually, with a hydrostatic test on the interval in 1910.157(f) Table L-1.

Sources: OSHA 29 CFR 1910.157 — Portable fire extinguishers

Get Workplace Safety Fundamentals certified online