Fire Extinguisher Classes Explained: A, B, C, D, K
Grabbing the nearest extinguisher isn’t always the right move — using the wrong class on the wrong fire can make things worse, not better.
Fire extinguishers are classed by the fuel they are made for: Class A ordinary combustibles, Class B flammable liquids and gases, Class C energized electrical equipment, Class D combustible metals, and Class K cooking oils and fats. OSHA 29 CFR 1910.157 sets placement by class, with 75 feet maximum travel distance for Class A and 50 feet for Class B.
The Five Classes
- Class A — ordinary combustibles: wood, paper, cloth, most plastics
- Class B — flammable liquids and gases: gasoline, oil, solvents, propane
- Class C — energized electrical equipment: wiring, panels, motors, powered tools
- Class D — combustible metals: magnesium, sodium, titanium, and similar alloys that can react explosively with water
- Class K — cooking oils and fats, common in commercial kitchens
Why Water Isn’t a Universal Answer
Water works well on Class A fires, but it’s genuinely dangerous on a Class C (energized electrical) fire because of shock risk, and it can cause a violent reaction on Class D combustible metal fires. Multi-purpose dry chemical extinguishers rated for A, B, and C cover the most common workplace scenarios, but Class D and Class K fires need their own specific, dedicated extinguishing agents.
Placement Requirements Under 1910.157
- Travel distance, Class A hazards: no more than 75 feet
- Travel distance, Class B hazards: no more than 50 feet
- Mounting height (40 lbs or less): top no more than 5 feet above floor
- Mounting height (over 40 lbs): top no more than 3.5 feet above floor
Inspection Isn’t a One-Time Thing
Extinguishers need a monthly visual inspection — checking the pressure gauge, pin, and seal — plus a more thorough annual maintenance inspection. Violations of the fire extinguisher standard can carry penalties up to $16,550 per instance, and a surprising number of citations come from something as simple as an extinguisher mounted too high or blocked by stored materials.
Frequently asked questions
What is a Class K fire extinguisher for?
Commercial cooking fires in oils and fats. Its wet-chemical agent saponifies the oil; water or a dry chemical can spread a grease fire.
How far apart do fire extinguishers have to be?
Travel distance to a Class A extinguisher may not exceed 75 feet and to a Class B extinguisher 50 feet (1910.157(d)).
How often are extinguishers inspected?
A visual inspection monthly and a maintenance check annually, with a hydrostatic test on the interval in 1910.157(f) Table L-1.
Sources: OSHA 29 CFR 1910.157 — Portable fire extinguishers
Get Workplace Safety Fundamentals certified online
Related guides
- The PPE Requirement Most Employers Miss: The Written Hazard Assessment
- Recordable vs. Reportable: What OSHA Actually Requires You to Do
- OSHA’s General Duty Clause: The Rule That Applies When No Other Rule Does
- Is Online Safety Certification Legit? What OSHA Actually Requires
- Free checklist: Workplace Safety Fundamentals Toolbox Talk Template
- Free checklist: Employee Certification Tracking Log