Wire Rope Inspection Checklist
A monthly thorough-inspection template matching OSHA 1910.179’s required certification record — date, inspector, rope identifier, and the specific conditions to check for.
Required Certification Record (1910.179)
- Date of inspection
- Signature of the person who performed it
- Identifier for the specific rope inspected
Broken Wires — Overhead/Gantry Cranes (ASME B30.2)
- 12 or more randomly distributed broken wires in one rope lay — remove from service
- 4 or more broken wires in a single strand within one lay — remove from service
- Two or more valley breaks in one lay — remove from service regardless of total count
Other Removal Conditions
- Reduction of rope diameter below nominal (core loss, corrosion, or wire wear)
- Kinking, birdcaging, crushing, or other structural distortion
- Corroded, cracked, bent, or improperly applied end connections
- Heat damage from any source
Don’t Forget
- A rope idle 1+ month needs a thorough inspection before returning to service
- A crane idle 6+ months needs a full periodic inspection, not just the monthly-level check
- When in doubt, a qualified person’s judgment governs — these are minimums, not a substitute for experience
Related certification: Overhead Crane Operator Certification
Related guides
- Do You Need Third-Party Certification for an Overhead Crane?
- OSHA Overhead Crane Inspection Requirements: Frequent vs. Periodic
- What Does "Designated Personnel" Actually Mean Under OSHA 1910.179?
- Overhead Crane Hand Signals: The Standard Every Operator Must Know
This checklist is a documentation aid and does not replace a qualified person’s judgment or your equipment manufacturer’s specific inspection requirements. © Shield Certificates — shieldcerts.com